New from A&D - The MS-70 / MX-50 / MF-50 Moisture Analyzer offering the latest in weighing technology implementing the Super Hybrid Sensor with moisture balance features that outshine the competition. Choose from three affordably priced models, designed to streamline the process of product moisture analysis. Additional uses include moisture analysis in the environmental, chemical, pharmaceutical industries, and more. The innovative Heat Chamber houses a 400 Watt Halogen heating lamp producing fast and accurate results aided by its uniquely designed SRA (Secondary Radiation Assist) Filter, which serves to radiate heat uniformly, protect the lamp from splatter during testing and provide a Progress Monitoring Translucent Glass Window. The SRA filter is easy to clean ensuring optimum performance while the halogen lamp is user replaceable. This of course will save time and money and minimize down time and labor costs. In-house tests put the MX-50 at the top of the league for accuracy in giving Sodium Tartrate a reading of 15.66% (+0.3/-0.1) moisture content with repeatability of 0.01% (S.D.), In-house factory tests comparing the top competing models, put the MX-50 at the top for accuracy using Sodium Tartrate as the standard. Repeatable readings of 15.66% (+0.3/-0.1) moisture content with repeatability of 0.01% were established. The Vacuum Fluorescent Display allows the results to be clearly displayed even in areas with poor lighting. The large keypads and intuitive embedded software makes the A&D MS/MX/MF moisture balance a breeze to use walking you through the convenient test setup parameters. Attention to the placement of handles make the unit safe to use minimizing burn related mishaps. Add it all up and A&D is Clearly a Better Value over all the other moisture balances on the market today! |
|
|
Sodium Tartrate Dihydrate is included for verifying the performance any of the A&D moisture analyzers. Sodium Tartrate Dihydrate is a chemical used in the industry as a standard since it contains 15.66% of a chemically uniform moisture. However, depending on the state of the preservation of the material the moisture of 0.09% or less adheres to the surface of it. Checking the performance of the moisture
balance is simple. Preheat the unit for about eight minutes at 160°C,
then put about 5 grams of Sodium Tartrate Dihydrate in the moisture balance.
The moisture content rate of 15.50 - 16.00% is obtained in a typical measurement. |
![]() Click For Hi-Res Image |
All
A&D Moisture Analyzers come with data acquisition software for exporting
data to a computer via the RS-232 interface. The MF-50 comes standard
with the WinCT balance communication software for
exporting weighing result to a MS Word or Excel.The MS-70 & MX-50 comes with Win CT Moisture (optional for the MF-50). Win CT Moisture exclusive Optimum Temperature Search (OTS) program is designed to display a graph of the moisture content rate change while measuring and makes it easier to set an appropriate analyzing mode setting with a connected PC. Users no longer have to go through a tedious trial and error process to determine optimum temperature and time for quick accurate analysis. ![]() Typically it takes days of trial and error to find optimal sample parameters. In just one 30-minute sample run, OTS automatically recommends the ideal time and temperature for a sample type. Because the OTS program helps the user distinguish between desired drying of moisture vs. the undesirable burning of the sample, OTS ensures quick accurate readings every time. In addition to OTS, WinCT-Moisture provides bidirectional data collection, graph time vs. moisture % and overlays multiple test graphs in different colors to visually compare results. Data can be exported to ExcelT or sent as an email attachment. The MX-50 can also be purchased with an optional Certified Temperature Calibrator (ONLY available for the MX-50 Moisture Balance). Calibration results can be output in the format that conforms to GLP, GMP, ISOC. All A&D moisture analyzers measure moisture thermogravimetrically. Thermogravimetric moisture analysis is based on the principles of vaporization of water during the during process. The moisture balances monitors the weight loss of a sample as the material is heated. The sample weight prior to heating and after reaching a steady-state mass after drying determines the moisture content. The halogen bulb produces the heating of the sample by infrared radiation. The thermogravimetric method offers advantages over moisture determination using a chemical method such as Karl Fisher Titration. Thermogravimetric moisture analysis is simple to perform and adaptable to many conditions verses Karl Fisher Titration can be subjective, and require the handling and disposal of solvents and potentially hazardous materials. |
|||||||||||||||||||||||||||||||||
|
A&D technology increases your productivity
|
A&D know-how gives superior analytical performance
|
||||||||||||||||||||||||||||||||
![]() |
![]() |
||||||||||||||||||||||||||||||||
| Progress
window for heating check Heating process can be checked through translucent window |
Easy
handling of the unit Ergonomically designed pan handle eliminates mishaps such burns when moving a hot sample tray into or out of the unit from either side. |
||||||||||||||||||||||||||||||||
|
Display Mode give you the choice of % moisture, % solids, weight, atro moisture or atro solids ATRO Moisture
content refers to a measurement of moisture content as compared to dry
weight. So for a
100 gram sample drying to 75 grams. Similar idea
for Dry content vs. ATRO dry content. |
|||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||
|
Click
any of the images for a high resolution close-up
|
|||||||||||||||||||||||||||||||||
|
A&D
MX/MF Specifications |
MS-70 | MX-50 | MF-50 | ||||
| Precision Discount Price | See Price HERE | See Price HERE | |||||
| Measurement Method |
400W
straight halogen lamp heating system with SRA filter & SHS Weighing
technology |
||||||
| Max Sample Weight Capacity | 71g |
51g |
51g | ||||
| Weight Resolution | 0.0001g |
0.001g |
0.002g | ||||
| Moisture Content Display | 0.001/0.01/0.1% |
0.01/0.1% |
0.05/0.1/1% | ||||
|
0.05% |
0.10% |
0.20% | ||||
| 0.01% | 0.02% | 0.05% | |||||
| Heating Technology |
Halogen
lamp (Straight type, 400W max, 5000 hours) |
||||||
| Heating Time |
The
heating time can be set in the range of 1 to 480 minutes, and increments
between 1-60 minutes in 1 minute intervals, 60 - 480 minutes in 5 minute
increments. |
||||||
| Drying Temperature | 50 - 200°C / (1°C increment) | ||||||
| Memory of Measurement Programs | 20 sets |
20
sets |
10 sets | ||||
| Measurement Programs |
Standard
Mode/Automatic Complete Mode/Timer Mode/Manual Mode |
||||||
| Measurement Mode |
Wet
base/Dry base/Solid content/Ratio |
||||||
| Display Type |
Large
VFD |
||||||
| Interface |
RS-232C
Standard |
||||||
| Data Memory Function | 100 |
100 |
50 | ||||
| Operating Temperature |
5-40°C(41-104°F)less
than 85% RH |
||||||
| GLP/GMP/ISO |
Available |
||||||
| Self Check Function |
Standard |
||||||
| Communication Software |
Win
CT Moisture (for MS-70 & MX-50 only) |
Win CT standard | |||||
| Sample Pan Size |
ø
85 mm / 3.4 inches |
||||||
| Power |
AC
100V to 120V (3A) 50/60Hz, Approx. 400Watts |
||||||
| Physical Dimensions |
215
(W) x 320 (D) x 173(H) mm 8.5" x 12.6" x 6.8" |
||||||
| Warranty |
60
month manufacturer's warranty |
||||||
| Weight |
Approx.
6 kg / 13.2 lbs |
||||||
| Standard Accessories |
20
Sample Pans, 2 Pan Handles, Tweezers, Spoon, Test Sample (30g of Sodium
Tartrate Dihydrate), CD-Rom Win-CT, Display Cover, Dust Cover, Instruction
Manual, Quick Reference Card, Power cable, 2 Fuses |
||||||
|
Download
the MX/MF-50 Instruction
Manual (2.2 MB) now |
|||||||
Download
this MS Powerpoint Presentation covering the design features of
the MX/MF Moisture Balance and overview of WinCT-moisture analyzer software.
Compare the performance results of the A&D MX/MF verses the Ohaus
MB-35, Ohaus MB-45, Mettler HB43, mettler-Toldeo HB53, Sartorius MA50,
Sartorius MA100, Sartorius MA45, Denver IR30 & Denver Instruments
IR200. |
|||||||
|
Warning
- Moisture balances
should not be used on any volatile organic sample with flash
points. Even a MSDS rating of 1. Samples with low flask
points like Acetaldehyde -38°C or MEK -4°C should not be used
with the A&D Moisture Balances and maybe you should look at Karl
Fisher as an alternative.
Although you might presently perform analysis with an oven on these sample the ovens typically have ventilation and a much larger cavity than the typical moisture balance that operates on the principles of TGA. In addition, with most moisture balances there is no ventilation so all the fumes remain inside the hood of the moisture balance. We strongly recommend you consult with a safety specialist always prior to using any moisture balances for your safety. |
|
Hot Buys | Analytical Balances | Baby Scales | Calibration Weights | Counting Scales | Commercial Floor Scales | Crane Scales | Industrial Platform & Bench Scales | Mechanical Balances | Moisture Balances | Pocket Scales | Portable Balances | Precision Toploader Balances | Price Computing Scales | USED & Demo Balances | Contact Us | Return Policy | Home Have Questions? Call 978-521-7095 or e-mail us your questions and we will assist you in your selection. Copyright